BITMAIN/ANTMINER

BITMAIN was established in 2013. S1–S5 are established for early mass production, S9 enters 16 nm, S17, S19, S21 to S23 continue to reduce J/TH; L, Z, E, KS and other series are expanded to other algorithms.

Product coverage
SHA-256RandomXKHeavyHashScryptEtHash / EtchashBlake3Blake256R14kHeavyHashEquihashX11HandshakeEaglesongBlake2SEtHashTensorityCryptoNightBlake2B Hydro coolingAir coolingImmersion liquid cooling
Current Direction

Where to go now

The S23 generation and ANTSPACE/ANTRACK put miners, cabinets, waterways and containers into the same system; non-BTC lines are still continuously updated according to the algorithm.

Miner Check

Miners must first distinguish

S, T, L, Z, E, KS, and AL are different product lines; Hyd., Imm., and 3U represent different cooling and deployment conditions.

Data Boundary

How to read the information

Company and product information is relatively complete. This site gives priority to official company, technical or regulatory information; when there is insufficient public history, only verifiable product nodes are described.

Product Families

Create a product map using series first

There may still be differences in air cooling, hydro cooling, hashrate and voltage within the same series; the series is just for finding the direction, and the complete model is the specification unit.

Company Timeline

Manufacturer history and product generations

S1 to S5: early mass production

The company was established and delivered S1; later S2, S3, S4, and S5 allowed ANTMINER to form a continuous SHA-256 product line.

S9 and 16 nm generation

S9 pushed the mainstream BTC ASIC to about 100 J/TH, becoming a representative that has existed in mining farms and the second-hand mobile phone market for a long time.

Multi-algorithm product expansion

Products such as L3+, Z9, E3, D3, A3 extend ANTMINER from BTC to Scrypt, Equihash, EtHash and other algorithms.

S17: 40 J/TH generation

The S17 series pushes SHA-256 energy efficiency to about 40 J/TH, but also leaves a lot of problems with second-hand mobile phone maintenance and batch differences.

S19 and S19 XP

S19 entered about 30 J/TH, S19 XP entered about 20 J/TH, and the hashrate density of air-cooled mines increased rapidly.

Hydro and Z15

S19 Hydro and ANTSPACE HK3 establish a water-cooling deployment route; Z15 ​​continues the Equihash product generation.

S21 and 10 J/T routes

S21, S21 Pro, S21 XP and water-cooling branches push products to the 10 J/TH level, and non-BTC lines such as L9, KS5 Pro, AL1 are updated simultaneously.

S23 and high-density systems

The new generation of S23 Hyd., S23e U2H and ANTSPACE/ANTRACK integrate machine energy efficiency, cabinets, waterways and containers into the same deployment problem.

AW1: deployment conditions and PUE limits

BITMAIN published AW1 exhibition details on October 8, 2026: two 20-foot containers house the server and cooling units, with eight racks, 376U and 120 kW of cooling capacity, supporting dry, wet and hybrid modes. Cooling capacity must not be read directly as IT load. The manufacturer states continuous operation from −35°C to 40°C. Its website states PUE as low as 1.11 under standard operating conditions; its official social post states 1.111. Both source formulations are retained. PUE compares total facility energy with IT equipment energy; it is not ASIC efficiency in J/TH. Check ambient conditions, cooling mode, actual load and service boundaries. These are manufacturer claims, not independent JGM Learn measurements. Exhibition does not prove delivery or guarantee equivalent efficiency at every site.

Products In Database

miners have been included, from new to old

Cross-series of the same brand are arranged in reverse order of production/release time, and then divided into years. Click on the individual machine page to view specifications, risks, position in the same series and data sources.

111 models
2026

2026 collection models

7 styles

The release order within the year is still from newest to oldest; the actual delivery batch and regional launch time may be different.

2025

2025 collection models

14 styles

The release order within the year is still from newest to oldest; the actual delivery batch and regional launch time may be different.

Antminer L11 Hyd 2U

Approximately 5775 W / Please use the complete hashrate version and the wall power consumption to convert

Scrypt MinerScrypt/hydro coolingLTC/DOGE merged miningHydro-cooled deployment

Antminer L11 Hyd 6U

Approximately 5676 W / Please use the full hashrate version and the wall power consumption to convert

Scrypt MinerScrypt/hydro coolingLTC/DOGE merged miningHydro-cooled deployment

Antminer L9 Hyd 2U

Approximately 5670 W / Please use the complete hashrate version and the wall power consumption to convert

Scrypt MinerScrypt/hydro coolingLTC/DOGE merged miningHydro-cooled deployment

Antminer L11

Approximately 3680 W / Please use the complete hashrate version and wall power consumption to convert

Scrypt MinerScrypt/air coolingLTC/DOGE merged miningAir-cooled deployment

Antminer L11 Pro

Approximately 3612 W / Please use the complete hashrate version and wall power consumption to convert

Scrypt MinerScrypt/air coolingLTC/DOGE merged miningAir-cooled deployment

Antminer S21+ Hyd

Approx. 4785 to 5925 W / Check the exact hashrate version and wall power

BTC ASIC MinerSHA-256/hydro coolingBitcoin miningHydro-cooled deployment

Antminer S23 Hyd. 3U

About 11020 W / About 9.5 J/TH

BTC ASIC Minerhydro-cooled BTC, below 10 J/THBitcoin miningHydro-cooled deployment

Antminer S21 XP+ Hyd

About 5500 W / Please use the complete hashrate version and wall power consumption to convert

BTC ASIC MinerSHA-256/hydro coolingBitcoin miningHydro-cooled deployment

Antminer S23 Hyd.

About 5510 W / About 9.5 J/TH

BTC ASIC Minerhydro-cooled BTC, below 10 J/THBitcoin miningHydro-cooled deployment

Antminer S19 XP+ Hyd

Approximately 5301 to 5567 W / Please use the full hashrate version and the wall power consumption to convert

BTC ASIC MinerSHA-256/hydro coolingBitcoin miningHydro-cooled deployment

Antminer S21e Hydro

Hashrate
288–332 TH/s
Power Consumption
4,896–5,644W @35°C
Efficiency
17 J/TH
Official variants
3 official variants
BS
BTC ASIC MinerEfficient BTC, 15-18 J/THBitcoin miningHydro-cooled deployment

Antminer E11

About 2340 W / About 0.26 J/MH

ETC ASIC minerETC high hashrate modelETC miningAir-cooled deployment

Antminer S19 XP Hyd 3U

Approximately 10600 W / Please use the complete hashrate version and wall power consumption to convert

BTC ASIC MinerSHA-256/hydro coolingBitcoin miningHydro-cooled deployment

Antminer S21e XP Hyd 3U

Approximately 11180 W / Please use the complete hashrate version and wall power consumption to convert

BTC ASIC MinerSHA-256/hydro coolingBitcoin miningHydro-cooled deployment
2024

2024 collection models

17 styles

The release order within the year is still from newest to oldest; the actual delivery batch and regional launch time may be different.

Antminer S21 Immersion

Approximately 5569 W / Please use the complete hashrate version and the wall power consumption to convert

BTC ASIC MinerSHA-256/immersion liquid coolingBitcoin miningLiquid cooling deployment

Antminer S21e XP Hyd

Approximately 5590 W / Please use the complete hashrate version and the wall power consumption to convert

BTC ASIC MinerSHA-256/hydro coolingBitcoin miningHydro-cooled deployment

Antminer S21+

About 3564 W / About 16.5 J/TH

BTC ASIC MinerEfficient BTC, 15-18 J/THBitcoin miningAir-cooled deployment

Antminer S21 XP Immersion

Approximately 4050 W / Please use the complete hashrate version and the wall power consumption to convert

BTC ASIC MinerSHA-256/immersion liquid coolingBitcoin miningLiquid cooling deployment

Antminer AL1 Pro

Approximately 3730 W / Please use the complete hashrate version and the wall power consumption to convert

ALPH ASIC MinerBlake3/air coolingALPH MiningAir-cooled deployment

Antminer S19 Pro++

Approximately 3250 W / Please use the complete hashrate version and wall power consumption to convert

BTC ASIC MinerSHA-256/air coolingBitcoin miningAir-cooled deployment

Antminer AL1

About 3510 W / About 225 J/TH

ALPH ASIC MinerALPH, about 225 J/THAir-cooled deploymentALPH Mining

Antminer L9

Approx. 3360 W / Approx. 210 J/GH

Scrypt MinerEfficient Scrypt, about 200-250 J/GHLTC/DOGE merged miningAir-cooled deployment

Antminer S21 XP Hydro

About 5676 W / About 12 J/TH

BTC ASIC MinerEfficient BTC, about 12 J/THBitcoin miningHydro-cooled deployment

Antminer S19j XP

Approximately 3247 W / Please use the complete hashrate version and the wall power consumption to convert

BTC ASIC MinerSHA-256/air coolingBitcoin miningAir-cooled deployment

Antminer DR7

Approximately 2730 W / Please use the complete hashrate version and wall power consumption to convert

Other PoW ASIC minersBlake256R14/air coolingOther PoW miningAir-cooled deployment

Antminer S21 XP

About 3645 W / About 13.5 J/TH

BTC ASIC MinerTop BTC, under 15 J/THBitcoin miningAir-cooled deployment

Antminer S19e XP Hyd.

Approx. 5280–5522 W / Approx. 22 J/TH

BTC ASIC Minerhydro-cooled BTC, about 22 J/THBitcoin miningHydro-cooled deployment

Antminer KS5 Pro

About 3150 W / About 150 J/TH

KAS ASIC MinerKAS high hashrate modelKAS MiningAir-cooled deployment

Antminer KS5

About 3000 W / About 150 J/TH

KAS ASIC MinerKAS high hashrate modelKAS MiningAir-cooled deployment

Antminer S21 Pro

About 3510 W / About 15 J/TH

BTC ASIC MinerExtremely efficient BTC, about 15 J/THBitcoin miningAir-cooled deployment

Antminer T19 Pro Hyd

Approximately 5170 W / Please use the complete hashrate version and the wall power consumption to convert

BTC ASIC MinerSHA-256/hydro coolingBitcoin miningHydro-cooled deployment
2023

2023 collection models

10 styles

The release order within the year is still from newest to oldest; the actual delivery batch and regional launch time may be different.

Antminer T21

Approx. 3610 W / Approx. 19 J/TH

BTC ASIC MinerMainstream BTC, about 19 J/THBitcoin miningAir-cooled deployment

Antminer KS3

Approximately 3188 to 3500 W / Please use the complete hashrate version and wall power consumption to convert

KAS ASIC MinerKHeavyHash/Air-cooledKAS MiningAir-cooled deployment

Antminer S21 Hydro

About 5360 W / About 16 J/TH

BTC ASIC MinerEfficient BTC, 15-18 J/THBitcoin miningHydro-cooled deployment

Antminer S21

About 3500 W / About 17.5 J/TH

BTC ASIC MinerEfficient BTC, 15-18 J/THBitcoin miningAir-cooled deployment

Antminer X5

1350 W / 6.37 J/kH

XMR ASIC MinerRandomX/air coolingXMR MiningAir-cooled deployment

Antminer Z15 Pro

2,650 W / approx. 3.15 J/KSol

ZEC ASIC minerEquihash Efficient GenerationZEC/ZEN MiningAir-cooled deployment

Antminer S19 K Pro

About 2760 W / About 23 J/TH

BTC ASIC MinerPrevious generation BTC, 20+ J/THBitcoin miningAir-cooled deployment

Antminer D9

Approximately 2839 W / Please use the complete hashrate version and the wall power consumption to convert

DASH ASIC MinerX11/air coolingDASH MiningAir-cooled deployment

Antminer E9 Pro

About 2200 W / About 0.6 J/MH

ETC ASIC minerEtchash, about 0.6 J/MHETC miningAir-cooled deployment

Antminer S19 Pro Hyd

Approximately 5221 W / Please use the complete hashrate version and the wall power consumption to convert

BTC ASIC MinerSHA-256/hydro coolingBitcoin miningHydro-cooled deployment
2022

2022 collection models

10 styles

The release order within the year is still from newest to oldest; the actual delivery batch and regional launch time may be different.

Antminer S19j Pro+

Approximately 3355 W / Please use the complete hashrate version and the wall power consumption to convert

BTC ASIC MinerSHA-256/air coolingBitcoin miningAir-cooled deployment

Antminer HS3

Approximately 2079 W / Please use the complete hashrate version and wall power consumption to convert

Other PoW ASIC minersHandshake/air coolingOther PoW miningAir-cooled deployment

Antminer K7

About 3080 W / About 48.5 J/TH

CKB ASIC minerCKB High Hashrate GenerationCKB MiningAir-cooled deployment

Antminer S19 XP Hydro

About 5346 W / About 20.8 J/TH

BTC ASIC Minerhydro-cooled BTC, 18-21 J/THBitcoin miningHydro-cooled deployment

Antminer T19 Hydro

Approximately 5438 to 5451 W / Please use the complete hashrate version and wall power consumption to convert

BTC ASIC MinerSHA-256/hydro coolingBitcoin miningHydro-cooled deployment

Antminer KA3

Approx. 3154 W / Approx. 19 J/TH

KDA ASIC MinerKDA high hashrate generationKDA MiningAir-cooled deployment

Antminer S19 XP

About 3010 W / About 21.5 J/TH

BTC ASIC MinerMainstream BTC, about 21.5 J/THBitcoin miningAir-cooled deployment

Antminer S19 Hydro

About 5451 W / About 34.5 J/TH

BTC ASIC Minerhydro-cooled BTC, 30-35 J/THBitcoin miningHydro-cooled deployment

Antminer E9

Approximately 1920 W / Please use the complete hashrate version and wall power consumption to convert

ETC ASIC minerEtHash/Air coolingETC miningAir-cooled deployment

Antminer S19 Pro+ Hyd

Approximately 5445 W / Please use the complete hashrate version and the wall power consumption to convert

BTC ASIC MinerSHA-256/hydro coolingBitcoin miningHydro-cooled deployment
2021

2021 collected models

5 styles

The release order within the year is still from newest to oldest; the actual delivery batch and regional launch time may be different.

2020

2020 collected models

5 styles

The release order within the year is still from newest to oldest; the actual delivery batch and regional launch time may be different.

2019

2019 collected models

11 styles

The release order within the year is still from newest to oldest; the actual delivery batch and regional launch time may be different.

Antminer S17+

Approximately 2920 W / Please use the complete hashrate version and wall power consumption to convert

BTC ASIC MinerSHA-256/air coolingBitcoin miningAir-cooled deployment

Antminer T17+

Approximately 3200 W / Please use the complete hashrate version and wall power consumption to convert

BTC ASIC MinerSHA-256/air coolingBitcoin miningAir-cooled deployment

Antminer S17e

Approximately 2880 W / Please use the complete hashrate version and wall power consumption to convert

BTC ASIC MinerSHA-256/air coolingBitcoin miningAir-cooled deployment

Antminer T17e

Approximately 2915 W / Please use the complete hashrate version and wall power consumption to convert

BTC ASIC MinerSHA-256/air coolingBitcoin miningAir-cooled deployment

Antminer S9k

Approximately 1310 W / Please use the complete hashrate version and the wall power consumption to convert

BTC ASIC MinerSHA-256/air coolingBitcoin miningAir-cooled deployment

Antminer S9 SE

Approximately 1280 W / Please use the complete hashrate version and wall power consumption to convert

BTC ASIC MinerSHA-256/air coolingBitcoin miningAir-cooled deployment

Antminer T17

Approximately 2200 W / Please use the complete hashrate version and wall power consumption to convert

BTC ASIC MinerSHA-256/air coolingBitcoin miningAir-cooled deployment

Antminer S17 Pro

Approximately 1975 to 2094 W / Please use the complete hashrate version and wall power consumption to convert

BTC ASIC MinerSHA-256/air coolingBitcoin miningAir-cooled deployment

Antminer Z11

About 1418 W / About 10.5 J/KSol

ZEC ASIC minerHistorical Equihash modelsZEC/ZEN MiningAir-cooled deployment

Antminer S17

About 2520 W / About 45 J/TH

BTC ASIC MinerHistorical BTC, 40-50 J/THBitcoin miningAir-cooled deployment

Antminer B7

Approximately 528 W / Please use the complete hashrate version and the wall power consumption to convert

Other PoW ASIC minersTensority/air coolingOther PoW miningAir-cooled deployment
2018

2018 collected models

19 styles

The release order within the year is still from newest to oldest; the actual delivery batch and regional launch time may be different.

Antminer S15

Approximately 1596 W / Please use the complete hashrate version and the wall power consumption to convert

BTC ASIC MinerSHA-256/air coolingBitcoin miningAir-cooled deployment

Antminer T15

Approximately 1541 W / Please use the complete hashrate version and wall power consumption to convert

BTC ASIC MinerSHA-256/air coolingBitcoin miningAir-cooled deployment

Antminer DR5

Approx. 1610 W / Approx. 46 J/TH

DCR ASIC minerDCR historical modelsDCR miningAir-cooled deployment

Antminer D5

About 1566 W / About 13.2 J/GH

DASH ASIC MinerDASH historical modelsDASH MiningAir-cooled deployment

Antminer S11

Approximately 1530 W / Please use the complete hashrate version and the wall power consumption to convert

BTC ASIC MinerSHA-256/air coolingBitcoin miningAir-cooled deployment

Antminer DR3

Approx. 1410 W / Approx. 181 J/TH

DCR ASIC minerDCR historical modelsDCR miningAir-cooled deployment

Antminer Z9

1,150 W / approx. 28.2 J/KSol

ZEC ASIC minerEquihash historical modelsZEC/ZEN MiningAir-cooled deployment

Antminer S9 Hydro

Approximately 1728 W / Please use the complete hashrate version and the wall power consumption to convert

BTC ASIC MinerSHA-256/hydro coolingBitcoin miningHydro-cooled deployment

Antminer S9j

Approximately 1350 W / Please use the complete hashrate version and wall power consumption to convert

BTC ASIC MinerSHA-256/air coolingBitcoin miningAir-cooled deployment

Antminer E3

Approx. 760 W / Approx. 4 J/MH

ETC ASIC minerEtHash historical modelsETC miningAir-cooled deployment

Antminer Z9 Mini

About 300 W / About 30 J/KSol

ZEC ASIC minerEquihash historical modelsZEC/ZEN MiningAir-cooled deployment

Antminer L3++

Approximately 942 to 1050 W / Please use the complete hashrate version and wall power consumption to convert

Scrypt MinerScrypt/air coolingLTC/DOGE merged miningAir-cooled deployment

Antminer B3

About 380 W / Please use the full hashrate version and wall power consumption to convert

Other PoW ASIC minersTensority/air coolingOther PoW miningAir-cooled deployment

Antminer S9i

Approximately 1290 to 1320 W / Please use the complete hashrate version and wall power consumption to convert

BTC ASIC MinerSHA-256/air coolingBitcoin miningAir-cooled deployment

Antminer B3 (780Hz)

Approximately 360 W / Please use the complete hashrate version and wall power consumption to convert

Other PoW ASIC minersTensority/air coolingOther PoW miningAir-cooled deployment

Antminer X3

Approximately 465 W / Please use the complete hashrate version and wall power consumption to convert

XMR ASIC MinerCryptoNight/Air coolingOther PoW miningAir-cooled deployment

Antminer V9

Approximately 1027 W / Please use the complete hashrate version and wall power consumption to convert

BTC ASIC MinerSHA-256/air coolingBitcoin miningAir-cooled deployment

Antminer T9+

Approximately 1432 W / Please use the complete hashrate version and the wall power consumption to convert

BTC ASIC MinerSHA-256/air coolingBitcoin miningAir-cooled deployment

Antminer A3

About 1275 W / About 1.56 J/GH

BTCB2 · Documented
SC ASIC minerSC historical modelsSC MiningAir-cooled deployment
2017

2017 collected models

5 styles

The release order within the year is still from newest to oldest; the actual delivery batch and regional launch time may be different.

2016

2016 collected models

2 styles

The release order within the year is still from newest to oldest; the actual delivery batch and regional launch time may be different.

2015

2015 collected models

1 style

The release order within the year is still from newest to oldest; the actual delivery batch and regional launch time may be different.

2014

2014 collected models

4 styles

The release order within the year is still from newest to oldest; the actual delivery batch and regional launch time may be different.

2013

2013 collected models

1 style

The release order within the year is still from newest to oldest; the actual delivery batch and regional launch time may be different.